Prestige 662H/HW Series User’s Guide
Chapter 37 SNMP Configuration 378
Figure 221 Menu 22 SNMP Configuration
The following table describes the SNMP configuration parameters.
37.4 SNMP Traps
The Prestige will send traps to the SNMP manager when any one of the following events
occurs:
Menu 22 - SNMP Configuration
SNMP:
Get Community= public
Set Community= public
Trusted Host= 0.0.0.0
Trap:
Community= public
Destination= 0.0.0.0
Press ENTER to Confirm or ESC to Cancel:
Table 130 Menu 22 SNMP Configuration
FIELD DESCRIPTION
SNMP:
Get Community Type the Get Community, which is the password for the incoming Get- and
GetNext requests from the management station.
Set Community Type the Set community, which is the password for incoming Set requests from
the management station.
Trusted Host If you enter a trusted host, your Prestige will only respond to SNMP messages
from this address. A blank (default) field means your Prestige will respond to all
SNMP messages it receives, regardless of source.
Trap:
Community Type the trap community, which is the password sent with each trap to the SNMP
manager.
Destination Type the IP address of the station to send your SNMP traps to.
When you have completed this menu, press [ENTER] at the prompt “Press ENTER to Confirm
or ESC to Cancel:
” to save your configuration, or press [ESC] at any time to cancel.
Table 131 SNMP Traps
TRAP # TRAP NAME DESCRIPTION
1 coldStart (defined in RFC-1215) A trap is sent after booting (power on).
2 warmStart (defined in RFC-1215) A trap is sent after booting (software reboot).
3 linkDown (defined in RFC-1215) A trap is sent with the port number when any of the
links are down. See the following table.
4 linkUp (defined in RFC-1215) A trap is sent with the port number.
Vista de pagina 377
1 2 ... 373 374 375 376 377 378 379 380 381 382 383 ... 562 563

Comentarios a estos manuales

Sin comentarios

APC AR8001 manuels

Manuels d'utilisation et guides de l'utilisateur pour Accessoires pour portoirs APC AR8001.
Nous fournissons des manuels en pdf 1 APC AR8001 à télécharger gratuitement par type de document : Fiche technique






Plus de produits et de manuels pour Accessoires pour portoirs APC

Modèles Type de document
AR8120BLK Fiche technique   APC Stabilizer plate (750mm) voor NetShelter VX 23inch racks\zwart, 2 pages
AR8150BLK Fiche technique   APC Adapter Kit 23" to 19" Mounting, 1 pages
AR7754W Manuel   APC AR7751W rack accessory, 2 pages
Smart-UPS RT 19" Guide d'installation   APC Smart-UPS RT 19", 2 pages
AR4702 Manuel   APC AR4702 rack accessory, 2 pages
AR8355 Manuel   APC NetShelter WX Vented Gland Plates, 1 pages
Narrow Vertical Cable Organizer Manuel   APC Narrow Vertical Cable Organizer, 2 pages
AR8176BLK Manuel   APC AR8176BLK rack accessory [en] , 1 pages
AR8008BLK Manuel   APC Horizontal Cable Organizer Side Channel 18 to 30 inch adjustment, 2 pages
AR8190BLK Manuel   APC AR8190BLK rack accessory, 2 pages
AR8450 Manuel   APC AR8450 rack accessory [en] , 2 pages
AR8167BLK Manuel   APC AR8167BLK rack accessory, 2 pages
AR8425A Manuel   APC Horizontal Cable Organizer 1U, 2 pages
AR7000A Manuel d'installation   APC AR7000A rack accessory, 4 pages
AR8129 Manuel   APC Cable Management Arm, 1 pages
AR8172BLK Manuel d'installation   APC AR8172BLK rack accessory, 1 pages
AR8165ABLK Manuel   APC AR8164ABLK rack accessory, 2 pages
AR8361BLK Manuel   APC NetShelter VX 42U Curved Front Door Black, 4 pages
AR8359 Manuel   APC NetShelter WX Caster Kit, 1 pages
Netbotz Rack Access PX - HID Spécifications   APC Netbotz Rack Access PX - HID, 38 pages