Chapter 33 Green Ethernet
XS1920 Series User’s Guide
265
Figure 186 Advanced Application > Green Ethernet
The following table describes the labels in this screen.
Table 130 Advanced Application > Green Ethernet
LABEL DESCRIPTION
EEE Select this to activate Energy Efficient Ethernet globally.
Auto Power
Down
Select this to activate Auto Power Down globally.
Port This field displays the port number.
* Use this row to make the setting the same for all ports. Use this row first and then make
adjustments to each port if necessary.
Changes in this row are copied to all the ports as soon as you make them.
EEE Select this to activate Energy Efficient Ethernet on this port.
Auto Power
Down
Select this to activate Auto Power Down on this port.
Apply Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the Save link on the top navigation panel to
save your changes to the non-volatile memory when you are done configuring.
Cancel Click Cancel to begin configuring this screen afresh.