E/LZB 119 1889 R1A INSTALLATION
12
MODEM SETUP
If a pair of modems is used to connect the SIM to the
System Manager, the modems must be configured for the
type of audio circuit that they are connected to. The
19A149786 drawing in the modem maintenance manual,
LBI-33031, lists parameter sets for several applications of
the ZyXEL U-1496 modem (standard modem supplied with
the SIM Modem Shelf, when ordered). For a 4-wire leased
telephone line application, use the parameter set for the “Site
Controller 4-Wire Leased Line” for the SIM end, and the
parameters set for the “System Manager 4-Wire Leased Line
(to site)” for the System Manager end. For a 2-wire dialup
telephone line application, use the parameter set for the “Site
Controller 2-Wire Dialup Line” for the SIM end, and the
parameter set for the “System Manager 2-Wire Dialup Line
(to site)” for the System Manager end. For other audio
circuit applications, determine the correct parameter set
from the ZyXEL manual supplied with the modem.
Use the following procedure to make changes to the
parameters in the ZyXEL U-1496 modem:
1. Press the up arrow key to enter the configuration
mode.
2. Press the down arrow key to go to a parameter
group.
3. Press the left or right arrow key to select the
desired parameter group.
4. Press the down arrow key to go to a parameter in
the selected parameter group.
5. Press the left or right arrow key to select the
desired parameter.
6. Press the down arrow key to view the current value
for the selected parameter.
7. If the current value is the desired value, press the
up arrow key and go on to the next parameter. If
the current value is not the desired value, press the
left or right arrow key to select the desired value.
8. When the desired value has been selected, press the
down arrow key to change the parameter to the
selected value and go on to the next parameter.
9. If the next parameter is in this group of parameters,
return to step 5. If the next parameter is not in this
group of parameters, press the up arrow key and
return to step 3.
After all parameters in all parameter groups have been
verified or reconfigured, use following procedure to save the
changes:
1. Press the up arrow key until a parameter group is
selected.
2. Press the right arrow key until “SAVE TO =
PROFILE 0” is displayed.
3. Press the down arrow key twice.
4. Press the right arrow key until “RESET =
PROFILE 0” is displayed.
5. Press the down arrow key.
SIM SETUP
Regardless of whether the SIM was installed at the site
or the factory, you must program the SIM to obtain the
desired operational characteristics for your specific system.
Note that in the character strings used to program
the SIM, the symbol
∧∧
is used for a single space
between characters. Also note that letters used in
these character strings are case sensitive.
NOTE
Programming Setup
Use the following procedure to set up a customer-
supplied IBM-compatible PC with terminal emulation
software (or a dumb terminal).
1. Configure PC (or Terminal): Select the serial COM
port to be used (generally COM1 or COM2), and
configure as follows:
Baud Rate = 19,200
Start Bits = 1
Data Bits = 8
Stop Bits = 1
Parity Bits = None
2. Connect PC (or Terminal): Connect the supplied
programming cable (Ericsson # RPM 113 2514)
from J4 on the front of the SIM to the serial COM
port of the PC (or terminal), as shown in Figure 4.
If the serial COM port of the PC (or terminal) is not
equipped with a male 9-pin, D-subminiature (DB-
9) connector, a customer-supplied adapter will be
required.