MAINTENANCE AE/LZB 119 1889 R1
A
19
MAINTENANCE
Note that in the character strings used to program
the SIM, the symbol
is used for a single space
between characters. Also note that letters used in
these character strings are case sensitive.
NOTE
APPLICATION SOFTWARE UPDATE
Use the following procedure to download new
application software into a SIM using a customer-supplied
IBM-compatible PC with terminal emulation software (or a
dumb terminal). Skip step 1 if the PC is already set up.
1. Set up the PC as follows:
Turn on the PC and wait until the DOS command
prompt appears (generally
C:\
).
Type
md
diagpc
to create a subdirectory named
diagpc
under the main (or root) directory of the
PC. (This subdirectory will be used for the SIM
Diagnostic PC program file and the new
application software program file.)
Copy the
newdiag.exe
file from the supplied
diskette to the new
diagpc
subdirectory in the PC.
(This is the SIM Diagnostic PC program file.)
Run the terminal emulation program in the PC.
Select the serial COM port to be used by the PC
(generally COM1 or COM2), and configure it as
follows:
Baud Rate = 19,200
Start Bits = 1
Data Bits = 8
Stop Bits = 1
Parity Bits = None
2. Copy the new application software program file
(generally ending in
-----.hex
) from the supplied
diskette to the new
diagpc
subdirectory in the PC.
3. Select the Download Mode as follows:
Connect the supplied programming cable (Ericsson
# RPM 113 2514) from J4 on the front of the SIM
to the serial COM port of the PC (or terminal), as
shown in Figure 5.
Personal Computer
IBM-Compatable
Serial COM Port
Program Disks
J4 J3
Programming Cable
RPM 113 2514
Figure 5 - SIM Download Programming Setup
Press
Ctrl + E
to get the SIM to echo the typed
characters, so that you will be able to see (on the
screen of the PC or terminal) what you type.
Type
set
bbr,bootMode
B6
and press the
Enter
key.
Type
run
global,Reset
(
)
and press the
Enter
key.
After the SIM has finished rebooting and is in the
Download mode of operation, the following
message will be shown on the SIM display:
Boot OS
Idle
Exit the terminal emulation program in the PC.
4. Download the Application Software to SIM as follows:
Start up the Diagnostic PC program by running the
file
newdiag.exe
located in the
diagpc
directory of
the PC. The Diagnostic PC Application Window
will then appear on the PC screen.
From the
Options
pull-down menu, select
Setup
to
display the Serial Port Configuration window.
In the Serial Port Configuration window, select the
serial COM port to be used (generally COM1 or
COM2), and configure it as follows:
Baud Rate = 19,200
Start Bits = 1
Data Bits = 8
Stop Bits = 1
Parity Bits = None