7. Product Specification
MSAP2000 Technical Manual V3.0 7-7
7.4. Central Office Power Supply Module (CoPSM)
Overview
The Central Office Power Supply Module (CoPSM) provides the COT Shelf
with over-voltage and over-current protected for electrical power inputs, as well
as isolated DC to DC power conversion.
The CoPSM can be paired together with another CoPSM on the COT Shelf, to
provide 1+1 power redundancy protection.
Features
And
Benefits
LEDs on the front panel indicate the CoPSM status, fault occurrences, and
fuse status.
Circuit protection for low input voltage and output over currents
Over current protection for input and output interfaces.
Over-temperature auto-protection.
Testing connection port located on the Front Panel.
Digital control and Alarm Reporting.
Function Diagram
Application
CoPSM is used in those shelf that is not required the RINGER for telephone
lines.
Modules CoPSMModules
DC
-36 ~ -72VDC
MSAP2000 Internal Power buses