Chapter 45 IEEE 802.1Q Tagged VLAN Commands
IES-612-51A User’s Guide
303
" The IES-612-51A accepts both tagged and untagged incoming frames on the
Ethernet ports.
The following example sets the IES-612-51A to accept only VLAN tagged Ethernet frames on
DSL port 3.
45.4.6 VLAN CPU Show Command
Syntax:
ras> switch vlan cpu show
This command displays the management VLAN (CPU). You can only use ports that are
members of this management VLAN in order to manage the IES-612-51A.
The following example sets VLAN ID 2 to be the CPU (management) VLAN.
45.4.7 VLAN CPU Set Command
Syntax:
ras> switch vlan cpu set <vid>
where
This command sets the management VLAN (CPU). You can only use ports that are members
of this management VLAN in order to manage the IES-612-51A.
The following example sets VLAN ID 2 to be the CPU (management) VLAN.
Figure 154 VLAN Frame Type Command Example
ras> switch vlan frametype 3 tag
Figure 155 VLAN CPU Set Command Example
ras> switch vlan cpu set 2
<vid> =
The VLAN ID. Valid parameter range = [1 – 4094].
Figure 156 VLAN CPU Set Command Example
ras> switch vlan cpu set 2