Omni 56K II and Omni 56K Plus II User’s Guide
Command Sets 5-15
COMMAND DESCRIPTION VALUE
Minimum scan time/line: 10 ms (normal); 5 ms (fine). st=2
Minimum scan time/line: 10 ms. st=3
Minimum scan time/line: 20 ms (normal); 10ms (fine). st=4
Minimum scan time/line: 20 ms. st=5
Minimum scan time/line: 40 ms (normal); 20ms (fine). st=6
Minimum scan time/line: 40 ms. st=7
+FDCS=vr,br,wd,l
n,df,ec,bf,st
Current session parameters; refer to the +FDCC command.
+FDIS=vr,br,wd,l
n,df,ec,bf,st
Current session negotiation parameters; refer to the +FDCC command.
+FDR This initiates document reception after receiving a phase C data command.
+FDT=df,vr,wd, ln Transmits a phase C data command: release the DCE to proceed with
negotiation.
+FET=n End of page or document command:
More pages; same document. n=0
End of document; another document follows. n=1
No more pages or documents. n=2
Procedure interrupt; another page follows. n=4
Procedure interrupt; end of document, another document follows. n=5
Procedure interrupt; end of document. n=6
+FK Regular fax abort command.
+FLID="string" Local ID string parameter.
+FLO=n Flow control options.
No flow control. n=0
Set the XON/XOFF software flow control. n=1
Set the CTS/RTS hardware flow control. n=2
+FLPL=n This command indicates the availability of documents for polling.
The DTE has no document available for polling. n=0
Comentarios a estos manuales