Omni 56K II and Omni 56K Plus II User’s Guide
5-34 Command Sets
COMMAND BIT DEC HEX FUNCTION AND DESCRIPTION REF.
0 to
255
0-FF To process the CND, silence must be detected for the
specified interval, in 20 ms units.
bit dec hex Bit-mapped register. +000
0 1 1 This causes CND information to be reported in raw
format.
2 4 4 This enables the sending of data calling tones (CNG).
3 8 8 Reverses the V.23 channel speed. Originate mode
modem speed (Send/Receive) 1200/75; Answer mode
modem speed (Send/Receive) 75/1200.
&N12
S48=
4 16 10 (Works with the &D1 command) DTR ON causes the
modem to dial the default number and DTR OFF
causes the modem to hang-up and reset to profile 0.
When the modem is idle (waiting for a command), it
does not dial any number when DTR changes from
ON to OFF.
bit Dec hex Bit-mapped register. +000
7 0 0 Select 'Mark' as the first signal of the V.23
handshaking sequence (default).
&N12
S52=
128 80 Select 'Space' as the first signal of the V.23
handshaking sequence (default).
&N12
bit dec hex +000 S56=
0 to
255
0-FF Hook flash detect time, in units of 10ms. A value of
zero uses country-specific default duration.
bit dec hex Bit-mapped register. +016 S57=
4 16 10 Enables the reporting of Class 1 capability in response
to +FCLASS=?
Bit
S-register bit number, 'b', used in 'ATSr.b=n' and 'ATSr.b=?'
Dec
Decimal value, 'x', used in 'ATSn=x'
Hex
Equivalent Hexadecimal value.
+nnn
Factory default when listed in 'Reference' column.
Note:
AT' is omitted when an AT command is referred to in the 'Reference' column.