VES-1000 Series Ethernet Switch
System Maintenance 2 11-7
Table 11-5 Menu 24.12 - Hardware Monitor
FIELD DESCRIPTION EXAMPLE
Status “Normal” indicates that this fan is functioning above the minimum speed. Normal
Voltage (V)
2
The power supply for each voltage has a sensor that is capable of detecting
and reporting if the voltage falls out of the tolerance range.
V2.0
Current This is the current voltage reading. 2.03
Max This field displays the maximum voltage measured at this point.
Min This field displays the minimum voltage measured at this point.
Tolerance (%) Five percent is the acceptable deviation from the nominal voltage. 5%
Status “Normal” indicates that the voltage is within an acceptable operating range at
this point.
Normal
COMMANDS:
r-Reset status Enter “r” to refresh all the counters in this menu. r
ESC-exit Press [ESC] to exit this menu and return to SMT menu 24. [ESC]
If an error is detected:
The associated Status field in Menu 24.12 — Hardware Monitor will display Error.
The ALM (alarm) LED on the front panel will light.
To clear an alarm, enter “r” in Menu 24.12 — Hardware Monitor.
2
The voltage levels displayed in the screen are for the VES-1012.