1
5. Remote-access message
The Routel reports any access from a remote-access PC (Router mode) to the
Routel to the Supervision PC. This, on the one hand, for security reasons, but also
because alarms occurring during the access of the remote PC would be lost on the
supervision PC (Routel memory flushed by the data reading from the remote-
access PC).
After the reception of a remote-access message, the Supervision PC is
automatically going to call the island concerned, refreshing and thus reading all the
addresses concerned and then displaying them in the alarm list.
The ‘Messaging remote accesses’ function is configurable within the Routel
(enable/disable).
The ‘Remote Access Messages’ received are logged into the Routel logfile and can
also be displayed on screen (configurable within nP32, enable/disable)
6. Supply supervision message
The Routel reports any power failure of the Routel to the Supervision PC (after the
power supply has been restored).
The ‘Supply Supervision Message’ function is configurable within the Routel
(enable/disable).
The received ‘Supply Supervision Messages’ are logged into the Routel logfile.
7. Display of the modem connection
Current modem connections are displayed on screen dynamically (status line).
8. Links window
The Links window displays anoverview of the connected islands and the number of
activated Routel addresses per island.
9. Log functions
Log (Private_Data\System\RoutelLog.txt) with text entries of all connections and its
triggers.
10. Configurable HDB-block reading
The standard upload and memorisation of HDB blocks is fully supported.
The messaging of the HDB message (25%), by which the AS triggers the reading of
the HDB data by the PC, can be configured per AS and per HDB block
(analogue/binary and MFA1-127 / MFA 128-256) (configuration with FBD, MFA60).
11. Manual Routel address activation and de-activation
To switch off the messaging of Routel addresses temporarily, the addresses of a
Routel island can be de-activated and re-activated manually, without having to stop
novaPro32.
Features Remote Access (Router)
1. Time-out for the telephone connection
It is possible to configure a time-out, after which a Router connection will be broken.
A message will be displayed 60 seconds before disconnection. The time-out can be
re-armed within the displayed dialogue.