43.6.2 Resetting to the Factory Default
Follow the steps below to reset the switch back to the factory defaults.
1 Enter
erase running config to reset the current running configuration.
2 Enter
write memory to save the changes to the current configuration file. If you want to
reset the second configuration file, use the
write memory command again with the
specified index number.
The following example resets both configuration files to the factory default settings.
sysname# erase running-config
sysname# write memory
sysname# write memory 2