ZyXEL Confidential
404XD3C0.docx
162/181
(4) The telnet connection fails.
12. [BUG FIX]
Symptom: System crashes.
Condition: Configure device by eWC sometimes cause crash.
13. [BUG FIX]
Symptom: In bridge mode ZyWALL at eWCÆBridge, Bridge IP address settings can
not be saved successfully.
Condition:
(1) Switch the ZyWALL to bridge mode.
(2) Go to eWCÆBridge page.
(3) Change "IP Address", "IP Subnet Mask", or "Gateway IP Address" then click
"Apply"
(4) Status shows "Configuration updated successfully" but the changes was not really
saved.
14. [BUG FIX]
Symptom: In SMT 24.11, the setting of DNS Service is displayed under bridge mode
Condition:
(1) Go to SMT 1, change Device Mode to bridge mode.
(2) After reboot, go to SMT 24.11, DNS Service incorrectly appear.
Modifications in V3.62(XD.0)b3 | 04/04/2004
1. [BUG FIX]
Symptom: CI command error, ZyWALL will show some CI commands which don't
belong to current command set.
Condition:
(1) Go to SMT 24.8, CI command mode.
(2) Type "ip dns system", ZyWALL will correctly print two available commands,
"edit" and "display".
(3) Type "ip dns sys", ZyWALL will unexpectedly print nine available commands
instead of two. Those extra seven commands are not under "ip dns system".
2. [BUG FIX]
Symptom: DHCP client cannot get address from router.
Condition:
(1) In eWCÆLANÆLAN, configure router as a DHCP server and set IP pool starting
address as 192.168.1.33.
(2) In eWCÆLANÆStatic DHCP, configure all rules in static DHCP table and the IP
addresses are 192.168.1.33~192.168.1.40.
(3) Use a PC which MAC address is not in the static DHCP table to get a IP address
from router.
(4) The PC cannot get the IP address.
3. [BUG FIX]
Symptom: The ZyWALL will reset the current eWC HTTP session even when the
LAN IP configuration is not successfully changed. Under this situation, users have to
re-log in the ZyWALL.
Comentarios a estos manuales