ZyXEL Confidential
404XD3C0.docx
17/181
Virtual IP 192.168.201.2, private IP 192.168.1.2, remote IP 0.0.0.0
(2) VPN client is Greenbow.
(3) After the tunnel is up, the Ping from VPN client and the reply is from the ZW35's
WAN IP (172.25.21.24) instead of 192.168.201.2.
13. [BUG FIX] SPR ID: 080217401
Symptom: Cannot recognize service "PCAnywhere_Data(TCP5631)" in firewall rule.
Condition:
(1) Reset to default romfile.
(2) Go to eWC>FIREWALL>Rule Summary, and then insert a new firewall rule.
(3) In eWC>FIREWALL - EDIT RULE, fill in "Rule Name" and select service
"PCAnywhere_Data(TCP5631)" to "Selected Service(s)" column.
(4) Click "Apply".
(5) In eWC>FIREWALL>Rule Summary, you can see the service change to
"Any(TCP)".
14. [BUG FIX] SPR ID: 080221671
Symptom: CI command "ip nat incikeport" had been removed in firmware 4.03.
Condition:
(1) Disable the engineer debug flag by "ATEN".
(2) Execute CI "ip nat incikeport" will fail.
15. [BUG FIX] SPR ID: 080307372
Symptom: OIDs for VPN does not work. Even after tunnel has been up for a while and
traffic has been passed, those OIDs just show 0 in all table.
Condition:
(1) Set up topology:ZW70---internet--VPN--internet-----ZW35(DUT)
(2) Setup an SNMP server (software on PC) on ZW35 WAN subnet.
(3) Add zyxel.mib and zyxel-zywall mib.
(4) Dial up VPN on DUT, generate some traffic through VPN.
(5) From the SNMP server, it's observed that following OIDs are always 0:
vpnTunnelTxPktCnt .1.3.6.1.4.1.890.1.6.1.3.1.1.3
vpnTunnelTxPktSize .1.3.6.1.4.1.890.1.6.1.3.1.1.4
vpnTunnelRxPktCnt .1.3.6.1.4.1.890.1.6.1.3.1.1.5
vpnTunnelRxPktSize .1.3.6.1.4.1.890.1.6.1.3.1.1.6
vpnTunnelDisPktCnt .1.3.6.1.4.1.890.1.6.1.3.1.1.7
vpnTunnelDisPktSize .1.3.6.1.4.1.890.1.6.1.3.1.1.8
16. [BUG FIX] SPR ID: 080313748
Symptom: PC at LAN B can't ping to PC at LAN C.
Condition:
Toplolgy:
10.1.1.21 10.21.10.0/24
|--------(W)ZWB(L)---PC1
---(W)ZWA(L)-------|
10.1.1.2 |--------(W)ZWC(DUT)(L)---PC2
Comentarios a estos manuales