00000000: 00 00 00 00 00 00 00 0C B9 08 47 0F 88 E1 00 39
00000016: A0 00 B0 52 01 B0 F2 E6 95 66 6B 03 0E 01 00 00
00000032: 0C B9 08 47 10 03 01 00 0C B9 08 47 10 03 FF FF
00000048: FF FF FF FF 00 00 00 00 00 00 00 00
Finally, the 0xA054 option is used for obtaining information on the PLC device
manufacturer and a number of statistics on the PLC logical links between the net-
work devices.
Choose the frame type (Ctrl-C to exit): 0xa054
Init:
Frame: Get Manufacturing String Request (0xA054)
Binary Data, 60 bytes
00000000: 00 B0 52 00 00 01 00 00 00 00 00 00 88 E1 00 54
00000016: A0 00 B0 52 00 00 00 00 00 00 00 00 00 00 00 00
00000032: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00000048: 00 00 00 00 00 00 00 00 00 00 00 00
Dump:
Frame: Get Manufacturing String Confirm (A055), HomePlug-AV
Version: 1.0
Status: Success
Length: 64 (0x40)
Manufacturer string: Intellon HomePlug AV Device
Binary Data, 86 bytes
00000000: 00 00 00 00 00 00 00 0C B9 08 47 0F 88 E1 00 55
00000016: A0 00 B0 52 00 40 49 6E 74 65 6C 6C 6F 6E 20 48
00000032: 6F 6D 65 50 6C 75 67 20 41 56 20 44 65 76 69 63
00000048: 65 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00000064: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00000080: 00 00 00 00 00 00
Dump:
Frame: Get Link Statistics Confirm (A031), HomePlug-AV
Version: 1.0
Status: Success
Link ID: fc
TEI: 00
Direction: Tx
MPDU acked......................: 1249
MPDU collisions.................: 271
MPDU failures...................: 0
PB transmitted successfully.....: 1628
PB transmitted unsuccessfully...: 0
Direction: Rx
MPDU acked......................: 886
MPDU failures...................: 0
PB received successfully........: 1539
PB received unsuccessfully......: 0
Turbo Bit Errors passed.........: 241
Turbo Bit Errors failed.........: 0
-- Rx interval 0 --
Rx PHY rate.....................: 93
PB received successfully........: 17
PB received failed..............: 0
TBE errors over successfully....: 26
TBE errors over failed..........: 0
-- Rx interval 1 --
Rx PHY rate.....................: 93
PB received successfully........: 15
Configuring a HomePlug AV PLC Network Under Linux 203