the number of possible PLC stations in the same PLC network (16 stations for
HomePlug 1.0 and 1.1 and 250 stations in HomePlug AV). Some values are
reserved for the ROBO mode or for particular implementations of the HomePlug
1.0 standard.
Segment Bursting and Contention-Free Access
Two particular modes, segment bursting and contention-free access, are used to
have access to a higher priority on the PLC network in order to send the successive
segments of a service block without waiting for mandatory contention windows
before transmitting the frames.
In the case of segment bursting, PLC stations with priority level CA3 can set the
CC (Contention Control) parameter to 1. It is then possible for the source station to
transmit two consecutive segments without waiting for a high contention value.
This mode improves the performance and can prove useful for applications of the
VoIP type demanding a particular priority exception.
Figure 3.21 illustrates the functionality of segment bursting, which makes it
possible for a PLC device to transmit a series of service blocks with maximum prior-
ity (CA3).
In the case of contention free access (CFA), the source station is allowed to send
all the segments with priority CA3 and to transmit seven consecutive MPDU by set
-
ting the CC field to 1.
Transmission Channel Functionalities 53
Figure 3.19 Tone map management between PLC devices