Chapter 43 System Commands
IES-612-51 User’s Guide
271
43.1.3.2 Log Messages
The following table lists and describes the system log messages.
Table 96 Log Messages
LOG MESSAGE TYPE DESCRIPTION
ADSL <port> Link
Up(SN=<seq no>): <ds
rate>/<us rate>!
or
ADSL Link Info: NM:<ds
NM>/<us NM>!
INFO An ADSL port established a connection.
port - port number
seq no - sequence number of the connection
ds rate - downstream rate
us rate - upstream rate
us NM - upstream noise margin
ds NM - downstream noise margin
ADSL <port> Link
Down(SN=<seq no>)!
WARN An ADSL port lost its connection.
port - port number
seq no - sequence number of the connection
ADSL <port> Link Loss
of Power Dying-Gasp
Event!
WARN The subscriber device connected to an ADSL port experienced a loss of
power (Dying-Gasp).
port - port number
Change time server to
none.
INFO The time server setting was changed to none.
Change time server to
TIME. IP:<ip>
Timezone: <time zone>.
INFO The time server protocol setting was changed to TIME. The time server’s IP
address and time zone are displayed.
Change time server to
DAYTIME. IP: <ip>
INFO The time server protocol setting was changed to DAYTIME. The time
server’s IP address and time zone are displayed.
Change time server to
NTP. IP: <ip>
Timezone: <time zone>
INFO The time server protocol setting was changed to NTP. The time server’s IP
address and time zone are displayed.
External alarm is
triggered!
WARN External alarm input was detected.
Ether <port> Link
Down(SN=N)!
WARN An Ethernet link is down.
port - 1 is ENET1, 2 is ENET2
SN - an internal sequencer number
Ether N Link Up(SN=N):
<speed>!
INFO An Ethernet link is up.
port - 1 is ENET1, 2 is ENET2
SN - an internal sequencer number
speed - Ethernet connection speed, for example 1000M or 100M
External alarm is
released.
INFO An external alarm is over and the input has returned to a normal state.
FAN RPM DOWN: dev:
<id> Limit:N value:N!
WARN A fan’s RPM went too low.
id - 1=Fan 1, 2=Fan 2, 3=Fan
Limit - minimum (low) fan (RPM)
value - the measured fan RPM
FAN RPM OK: dev: <id>
Limit:N value:N!
INFO A fan’s RPM returned to the normal range.
id - 1=Fan 1, 2=Fan 2, 3=Fan 3
Limit - maximum (high) or minimum fan (RPM) that had been breached
value - the measured fan RPM