Chapter 44 Alarm Commands
IES-612-51 User’s Guide
278
44.2.2 Alarm Port Show Command Example
This example shows the results of using this command.
44.2.3 Alarm Port Set Command Example
The following example has the IES-612-51 record only critical alarms on DSL port 7.
ras> alarm port show
Press any key to continue, 'e' to exit, 'n' for nopause
no ifindex severity
----- ---------- -----------
01 01 minor
02 02 minor
03 03 minor
04 04 minor
05 05 minor
06 06 minor
07 07 minor
08 08 minor
09 09 minor
10 10 minor
11 11 minor
12 12 minor
13 13 minor
14 14 minor
15 15 minor
16 16 minor
17 17 minor
18 18 minor
19 19 minor
20 20 minor
Press any key to continue, 'e' to exit, 'n' for nopause
ras> alarm port set 7 critical
Vista de pagina 277