Chapter 54 ADSL Commands
IES-612-51 User’s Guide
343
These counters are also used in the alarm profiles (see Section 44.1 on page 275).
54.4.6 1 Day Performance Command Example
An example is shown next.
See Table 137 on page 342 for details about these counters.
eSs The number of Errored Seconds that have occurred within the 15-minute period.
inits The number of link ups and link downs that have occurred within the 15-minute
period.
sesl The number of Severely Errored Seconds that have occurred within the 15-
minute period.
uasl The number of UnAvailable Seconds that have occurred within the 15-minute
period.
Table 137 15 Minute Performance Counters (continued)
LABEL DESCRIPTION
Figure 162 1Day Performance Command Example
ras> statistics adsl 1dayperf 10
Port 10 current 1 day elapsed time:7827 sec (Link UP)
Current 1 Day Perf ATUC ATUR
lofs 0 0
loss 0 0
lols 0 -
lprs - 0
eSs 0 0
inits 1 -
sesl 1 0
uasl 0 0
Port 10 previous 1 day elapsed time:0 sec
Previous 1 Day Perf ATUC ATUR
lofs 0 0
loss 0 0
lols 0 -
lprs - 0
eSs 0 0
inits 0 -
sesl 0 0
uasl 0 0