Chapter 16 xDSL Port Setup
IES-1248-51V User’s Guide
136
16.11.1 PPVC Setup Members Screen
Use this screen to add and remove member PVCs.
Note: The member PVCs must be created on the subscriber’s device.
To open this screen, click Basic Setting > xDSL Port Setup > PPVC Setup.
Then, click a PPVC’s member number to open the PPVC Setup Members screen.
Figure 63 PPVC Setup, Edit
The following table describes the labels in this screen.
Table 25 PPVC Setup, Edit
LABEL DESCRIPTION
Port This is the port for which you are viewing or configuring settings.
Index This field displays the number of the member PVC.
VPI/VCI This field displays the Virtual Path Identifier (VPI) and Virtual Circuit
Identifier (VCI). The VPI and VCI identify a channel on this port. The
subscriber’s device must create this PVC.
VC Profile This shows which VC profile this channel uses for downstream traffic
shaping. The VC profile for upstream policing also displays if the
channel is configured to use one.
Level This field displays the number of the member PVC’s priority queue.
Delete Click Delete to remove a member PVC from the PPVC.
Clicking Delete saves your changes to the IES-1248-51V’s volatile
memory.
The IES-1248-51V loses these changes if it is turned off or loses
power, so use the Config Save link on the navigation panel to save
your changes to the non-volatile memory when you are done
configuring.
Add Use this section of the screen to add or modify a member PVC.
VPI Type the Virtual Path Identifier for this member PVC.
VCI Type the Virtual Circuit Identifier for this member PPVC. This PVC
cannot overlap with any existing PVC’s on this port.
DS VC Profile Use the drop-down list box to select a VC profile to use for this
channel’s downstream traffic shaping.
US VC Profile Use the drop-down list box to select a VC profile to use for this
channel’s upstream traffic. The IES-1248-51V does not perform
upstream traffic policing if you do not specify an upstream VC profile.