Chapter 41 PVC Upstream Limit
IES-1248-51V User’s Guide
302
The following table describes the labels in this screen.
Table 102 PVC Upstream Limit
LABEL DESCRIPTION
Enable Rate Limit Select this to set a limit on the upstream transmission rate for the
specified PVC. Clear this if there is no limit.
Rate This field has no effect unless Enable Rate Limit is selected.
Enter the maximum upstream transmission rate, in kbps, for the
specified PVC.
Port Use this drop-down list box to select the port for the PVC for which
you wish to configure the maximum upstream transmission rate.
VPI Type the Virtual Path Identifier for the PVC for which you wish to
configure the maximum upstream transmission rate.
VCI Type the Virtual Circuit Identifier for the PVC for which you wish to
configure the maximum upstream transmission rate.
Apply Click Apply to save the settings. The settings then display in the
summary table at the bottom of the screen.
Clicking Apply saves your changes to the IES-1248-51V’s volatile
memory. The IES-1248-51V loses these changes if it is turned off or
loses power, so use the Config Save link on the navigation panel to
save your changes to the non-volatile memory when you are done
configuring.
Cancel Click Cancel to begin configuring the fields afresh.
Show Port Select a port for which you wish to view information.
Index This field displays the index number for each PVC. Click it to edit the
settings for the maximum upstream transmission rate.
Type This field displays what type of PVC the specified PVC is.
Port This field displays the port number for the specified PVC.
VPI This field displays the Virtual Path Identifier for the specified PVC.
VCI This field displays the Virtual Circuit Identifier for the specified PVC.
Rate This field displays the maximum upstream transmission rate for the
specified PVC. This has no effect, however, unless Enable Rate Limit
is enabled.
Select
Enable
Select the check box in the Select column for an entry, and click
Enable to activate the limit on the upstream transmission rate for the
select PVC(s).
Select
Disable
Select the check box in the Select column for an entry, and click
Disable to deactivate the limit on the upstream transmission rate for
the select PVC(s).
Select All Click All to mark all of the check boxes.
Select None Click None to deselect all of the check boxes.