Chapter 44 Alarm
IES-1248-51V User’s Guide
312
eqpt (10006)warm_start info System warm-start.
eqpt (10007)alm_input critical There is an external alarm input.
eqpt (10008)voip_battery_fail critical There is a VoIP battery fault.
eqpt (10009)voip_clocl_fail critical There is a VoIP clock fault.
eqpt (10010)voip_ringer_fault critical The IES-1248-51V cannot ring due
to a hardware fault on the ringer
chip.??
sys (15000)reboot info The system restarted.
sys (15001)aco info An administrator cutoff (canceled)
an alarm.
sys (15002)alm_clear info An administrator cleared the
alarms.
sys (15003)login_fail minor V Someone used the wrong name or
password and failed to log in.
sys (15004)anti_spoofing minor The IES-1248-51V has detected the
same MAC address on more than
one subscriber port.
enet (20000)up info A Gigabit Ethernet interface is up.
enet (20001)down major V A Gigabit Ethernet interface is
down.
voip (25000)voip_temp_error critical The temperature of VoIP module
has reached 165 °C. The IES-1248-
51V releases this alarm when the
temperature goes down to 150 °C.
voip (25001)voip_dc_power_fail critical A DC power fault.
voip (25002)voip_ac_power_fail critical An AC power fault.
voip (25003)voip_ring_timer_fail info A firmware fault occurs when the
IES-1248-51V fails to start in SIP
mode.
voip (25004)voip_ring_rsrce_fail info The number of current incoming
VoIP calls has exceeded the total
RENs (ringer equivalency numbers)
the IES-1248-51V can support.
The IES-1248-51V only supports 1
REN for each subscriber port at the
time.
voip (25505)voip_ring_chd_fail info This alarm is no longer used.
Table 106 Alarm Descriptions (continued)
ALAR
M
CONDITION
SEVERIT
Y
CLEAR
ABLE
DESCRIPTION
Comentarios a estos manuales